Note:
The menu item
Suction turbine
is only visible
in suction systems.
Set a Time (full hours), at which the hopper gets refilled, regardless how full it is at
this time.
At the same time the purification of the boiler will take place.
This adjustment matches Cleaning/Filling.
Frequency for storage room suction systems in pulse mode, only for vacuum
systems.
Pause time for storage room extractor motor - suction system in pulse mode. If pau-
se time = 0 then no pulse mode.
Run time of burner auger until next Suction Interval.
The hopper is filled at this time regardless whether it is empty or not.
• 175 min = 12 – 20 kW
• 225 min = 25 – 32 kW
• 90 min = 36 – 56 kW
Back to the menu
Pellematic
.
PE 567 EN 1.1