Malfunction report
167
Suction fan unplugged
ڃ
Connect up suction fan
Storage room auger motor
unplugged
ڃ
Connect up storage room motor
13.17 Ashbox full (Fault 5044) – Ash Warning (Fault 5053)
Display:
[5044] PE Ashbox full
Description:
Moter doesn’t reach the normal speed after 3 attempts.
Display:
[5053] PE Ash Warning
Description:
Ash-box nearly full
Cause and Remedy:
Ash-box full
ڃ
Clear ash-box
Ash-box not completely
closed
ڃ
Close ash-box
End-switch defect
ڃ
Replace end-switch
13.18 Ball lock (Smart and Condens only – Fault 5045)
Display:
[5045] PE Ball lock
– Smart and Condens only
Description:
No pellets detected from capacitive sensor (KAP RA)
Cause and Remedy:
Pellet reserves depleted
ڃ
Refill storage-Room / supply tank
Capacitve sensor RA
defect
ڃ
Replace Capacitve sensor RA
13.19 Burner Motor / Ash box full (SMART and Condens only – Fault 5047)
Display:
[5047] Burner Motor /Ash box full
- SMART only
Description:
The alarm text is displayed after the motor has made 3 unsuccessful attempts
to reach the normal speed of the external de-ashing system.
Cause and Remedy:
Ash box is full
ڃ
Empty ash box
Rotation of burner auger
or ash auger is blocked
ڃ
Ensure rotation of auger
13.20 Container cover open (PEB only – Fault 5052)
Display:
[5052] PE Container cover open
Description:
Container cover open (PEB only) – Input AK
Cause and Remedy:
Cover open
ڃ
Close cover
End-switch defect
ڃ
Replace end-switch
13.21 Pellets Warning (Fault 5054)
Display:
[5054] PE 1 Pellets Warning
Description:
Measured pellets capacity (AE2) is below the threshold
Cause and Remedy:
Pellets nearly empty or
empty
ڃ
Fill up with pellets
Sensor unpuged (AE2)
ڃ
Connect plug
Parameter set incorrectly
ڃ
Check settings in menu Level detection sys-
tem (protected access)
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
Summary of Contents for PE 08
Page 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Page 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Page 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Page 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Page 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Page 168: ......
Page 169: ......