Setting of the
boiler setpoint temp
.
Note:
If heating controller demands a higher temp than the adjusted
regulation temp
,
the heating controller sets the regulation temp.
The
switch off temp
will be raised parallel to the regulation temp.
Reaching the Switch Off Temp, the boiler switches off.
In case the boiler temp drops under
switch off temp
minus
switch on hyst
, the boi-
ler activates again (as long as a burner request exists).
Adjusting the boiler performance is only possible inside the learned boiler size.
AGT Minimum is to regulate of the boiler performance.
If the Flue gas minimum temperature falls below, the boiler power increases inde-
pendently of the boiler temperature,
Displayed only with connected flue gas sensor.
Delay of the Delivery System relative to the burner auger – only at auger systems.
Choose between 2 types of regulating the burner:
Standard: Boiler runs in accordance with the burner demand of the heating
controller.
Impuls: Boiler starts when the heating controller send a one-time impulse and swit-
ches off when the Switch Off Temperature is reached.
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
Summary of Contents for PE 08
Page 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Page 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Page 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Page 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Page 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Page 168: ......
Page 169: ......