Solar settings
101
Set the solar pump pulse programme for solar circuit PRIO 2.
Only for solar circuit PRIO 2 it is necessary to set the solar pump pulse programme.
After the scavenging period of solar circuit PRIO 2 follows the scavenging interval
of both solar circuits.
After the scavenging interval follows the scavenging time.
During the scavenging time the solar circuit checks, if there is a new demand for
PRIO 1 or not.
If there is a demand for solar circuit 1, the pump runs, if not the scavenging period of
solar circuit 2 starts.
If during the scavenging period of solar circuit 2 there is a demand from solar circuit
1, it will be immediately fulfilled.
Note:
PRIO Runtime
,
PRIO break time
and
PRIO scavenging time
are only adjustable
if
PRIO Mode
is set to
Off
.
This setting only appears with two solar circuits with two pumps.
The procedure is the same as with one pump. Additionally both pumps can run in
parallel. If the temperature difference between collector and TPU lower sensor from
the solar circuit with PRIO A is higher than the temperature difference, both solar
circuits run parallel. The parameter value is only in solar circuits with PRIO A visible
and adjustable.
Timing chart for
2 solar circuits with 1 pump and 1 diverter Valve
and
2 solar circuits with 2 pumps
(solar cir-
cuit 1 ... Prio 1, solar circuit 2 ... Prio 2):
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
Summary of Contents for PE 08
Page 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Page 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Page 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Page 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Page 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Page 168: ......
Page 169: ......