44871001TH Rev.6
4-49
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.22 Eject Motor
(1) Remove the Scanner unit. (Refer to 4.2.8)
(2) Remove the Cover Assy Stacker. (Refer to 4.2.16)
(3) Remove the Cover Assy Rear. (Refer to 4.2.20)
(4) Remove the Guide-Eject-Lower-Assy. (Refer to 4.2.21)
(5) Remove two screws (Silver) . Remove the Plate-Gear-Exit and Gear .
(6) Remove two screws (Silver) . Remove the Eject-Motor .
(7) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).