44871001TH Rev.6
4-54
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.28 Lever In Sensor / Lever WR Sensor / Photo Interrupter
(1) Separate the Front Assy. (Refer to 4.2.23)
(2) Separate the Roller-Pressure and Roller Regist. (Refer to 4.2.26)
(3) Remove two screws (Black) . Remove the Holder-Sensor .
(4) Remove the Lever-In-Sensor . Remove the Spring-Sensor .
(5) Remove the Lever-WR-Sensor . Remove the Spring-Sensor .
(6) Remove two Photo Interrupter .
(7) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Make sure that the latch B of Holder-Sensor has engaged the latch A of the
Front.
⑦
①
①
②
③
④
⑤
⑥
B
A