Oki Data CONFIDENTIAL
44871001TH Rev.6
5-6
5. Lubricating point
⑥
44359201PA Frame-Assy. -MPT/
44564201PA Frame-Assy-Manual (MB461/MB461+LP)
⑦
44564001PA Guide-Assy-Eject-U
Roller-Pinch
Shaft-Idle-Dup
EM-30LP Class B
Apply a normal amount of
MOLYKOTE (EM-30LP) to the
hatched areas.
(Center of shaft)
EM-30LP Class A
Apply a normal amount of
MOLYKOTE (EM-30LP) to the
hatched areas.
(Side of roller and ditch of shaft)
(The other side is also the same.
: Two places in total)
Shaft-Idle-Dup
Roller-Pinch
Spring-Torsion-Pinch
Note:1
Note:1
Gear-Idle_Exit (Z38)
EM-30LP Class B x4
Apply a normal amount of MOLYKOTE (EM-30LP) to
the whole circle of gear teeth. Of 4pcs
EM-30LP Class C
Apply a normal amount of MOLYKOTE
(EM-30LP) to surface of the post (bearing
portion), the flange portions.
Summary of Contents for MB461MFP
Page 1: ...MB461 MB471 MB491 MB491 MB491 LP MPS4200mb MPS4700mb Maintenance Manual 031314C ...
Page 72: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 3 21 3 MFP INSTALLATION Sample MB471 Sample MB491 ...
Page 114: ...44871001TH Rev 6 4 36 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS ...