44871001TH Rev.6
4-39
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
(8) Remove the Cover Assy Stacker .
(9) Installing is performed by the reverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate moter).
2. Clamp together the screw and the FG-Film.
⑨
⑧
⑤
④
③
③
Closed the Cover Assy Stacker
Opened the Cover Assy Stacker
Release lever
⑥
(5) Remove two screws (Silver) . Remove the Cover-Eject .
(At this moment, Plate-Rear is also removed. Be careful not to damage FG film.
FG film is inserted between and . )
(6) With the Cover Assy Stacker closed, detach Lever-Link-Fuser (on both sides)
from the Fuser Assy release lever by using a flat-head screwdriver or something.
(7) With the Cover Assy Stacker opened, remove Spring-Stacker (on both sides).