Path 1: Initialization of EEPROM (Flash
EEPROM)
<Processing>
Initializes EEPROM with the default values of the program. Correction values of the engine
become the values before adjustment.
<Operation and start timing>
This initialization can be performed with the maintenance mode's menu on the operation
panel.
- System menu:
INITIALIZE EEPROM
Note:
Restart the printer after initialization.
Path 2: Storing factory default settings in the flash memory (EEPROM
Flash)
<Processing>
Stores all EEPROM data in the factory default setting area of the flash memory.
<Operation and start timing>
This storing can be performed with the maintenance mode's menu on the operation panel.
- System menu:
SAVE DEFAULT SET
.
Path 3: Restoring factory default settings in the EEPROM (Flash
EEPROM)
<Processing>
Writes a part of information (*1) of the EEPROM factory default settings saved in the flash
memory into the EEPROM.
*1: Printer data, media registration data, adjustment parameters (except life-limited parts
counters)
<Operation and start timing>
Operation can be executed with the user mode's menu or maintenance mode's menu on the
operation panel.
- System menu:
SET ALL TO DEFAULT
(user mode)
- System menu:
LOAD DEFAULT SET.
(maintenance mode)
Note:
Restart the printer after loading the settings.