OKI Data Infotech Corporation CONFIDENTIAL
Chapter 2 Inspection and Maintenance
2-10
2.9
Parts Requiring Periodic Replacement
Parts requiring periodic replacement are those that wear with the printer's normal operation. As
preventive maintenance, we recommend their regular replacement.
Table 2-1 Parts that require periodic replacement
Part name
Part code
Timing of replacement warnings *2
Remark
Total print length
0 to 50 km
Total print length
51 to 100 km
1 PUMP-TUBE-ASSY
(supply pump tube)
U00130797000 160h warning is
displayed
180h error
Same as on the
left
Replace when the
warning is displayed.
2 CAP, MW
U00131094001 3 years
Same as on the
left
Can be replaced only
when malfunctioning *1
3 MOTOR(CAP)-UD
U00112511200 2 years
Same as on the
left
Can be replaced only
when malfunctioning *1
4 PUMP F ASSY, MW
U00130624700 180h
Same as on the
left
Can be replaced only
when malfunctioning *1
5 Y-DRIVE- MOTOR-ASSY U00130619200 17 km
Same as on the
left
Can be replaced only
when malfunctioning *1
6 DRIVING PULLEY UNIT,
MW
U00130614600 3 years
Same as on the
left
Can be replaced only
when malfunctioning *1
7 SUPPLY PUMP, MW,
LCIS, Lc-Y
(supply pump assy)
U00132600300 160h warning is
displayed
180h error
Same as on the
left
Replace when the
warning is displayed.
(LCIS model)
8 SUPPLY PUMP, MW,
LCIS, Lm-K
(supply pump assy)
U00132601400 160h warning is
displayed
180h error
Same as on the
left
Replace when the
warning is displayed.
(LCIS model)
9 SUPPLY PUMP, MW,
LCIS, C-M
(supply pump assy)
U00132602500 160h warning is
displayed
180h error
Same as on the
left
Replace when the
warning is displayed.
(LCIS model)
10 Other parts
Depends on the
printer conditions
Same as on the
left
Can be replaced only
when malfunctioning *1
*1 Not covered by the guarantee
*2 Covered by the guarantee if malfunctioning before the warning