OKI Data Infotech Corporation CONFIDENTIAL
Chapter 6 Parts Replacement (Disassembly/Reassembly)
6-19
4.
Disconnect the two connectors
connected to the motor.
5.
Remove the
BRACKET(Y-MOTOR-SUPPORT) and
the BRACKET(DSE64B-MAIN)-MW with
five fixing screws, and then remove the
Y-DRIVE-MOTOR-ASSY and the
DRIVING PULLEY together.
6.
Remove the four screws, and remove
the BRACKET(Y-MOTOR-SUPPORT)
from the motor.
Note
Do not detach:
- BRACKET-DSE64B-MAIN-MW; and
- BRACKET-DSE64B-SUB-MW
from the PULLEY(Y-MOTOR-36Z)-S2M-MW
attached to the Y DRIVE MOTOR.
Note that the rotation axis adjustment has
been completed for the
PULLEY(Y-MOTOR-36Z)-S2M-MW with the
two brackets above installed.
BRACKET(DSE64B-MAIN)-MW
TIMING-BELT-Y
DRIVING PULLEY
BRACKET(Y-MOTOR-SUPPORT)
Y-DRIVE-MOTOR-ASSY
(including the TIMING-BELT-Y)
BRACKET(Y-MOTOR-SUPPORT)
BRACKET-DSE64B-SUB-MW
BRACKET(DSE64B-MAIN)-MW
PULLEY(Y-MOTOR-36Z)-S2M-MW
Summary of Contents for IP-6620
Page 567: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 5 Appendix 4 Blower Fan Wiring Diagram...
Page 568: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 6 Appendix 5 Actuator Wiring Diagram...
Page 572: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 10 Appendix 9 Subtank Unit Wiring Diagram...