45530603TH Rev.2
5-12
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
Item
Settings
Functions
Admin
Setup
Panel
Setup
Near Life Status Enable
Disable
Sets the display control of LCD when a
Near-Life warning for drum, fuser, and
belt occurs.
When enabled, displays the near- life
warning.
When disabled, do not display the near-
life warning. (Nor outputted on Attention
LED/ PJL/ MIB / Web)
The status where the device is
temporarily recovered by opening and
closing the cover after life duration error
occurs (Life warning) is not included.
Near Life LED
Enable
Disable
Sets the LED lighting control when a
near-life warning of toner, drum, fuser,
belt and waste toner box occurs.
When enabled, Attention LED lights*.
When disabled, Attention LED lights
out.
The status where the device is
temporarily recovered by opening and
closing the cover after life duration error
occurs (Life warning) is not included.
*For a drum, fuser, belt, and waste
toner box, it is applied only when “Panel
Setup”- “Near Life Status” is “Enable”.
For a toner, it is applied regardless of
the setting of “Panel Setup” – “Near
Life Status”.
Idle Display
Toner Gauge
Paper Size
Selects information displayed on the
standby screen. When paper size is
selected, paper size in each tray is
displayed. Toner gauge is the default.
Panel
Brightness
During
Operating
5
to
31
Adjusts the brightness of the operation
panel LCD (backlight brightness).
The brightness set in this setting is
applied during the panel operation.
Panel
Brightness
While Power
Save
0
1
to
5
to
31
Adjusts the brightness of the operation
panel LCD (backlight brightness).
The brightness set in this setting is
applied after a lapse of the time set by
the panel backlight timer from the last
operation.
Item
Settings
Functions
Admin
Setup
Panel
Setup
Panel Backlight
Timer
10
to
30
to
300
Adjusts time (second) to apply the panel
brightness while power save from the
last operation.
Front Lamp
Mode 1
Mode 2
Off
Sets whether to operate the lamp in the
front side of the device.
Time
Setup
Date Format
yyyy/mm/dd
mm/dd/yyyy
dd/mm/yyyy
Sets a date display format.
* The default value varies depending on
the destination.
ODA:mm/dd/yyyy , OEL:dd/mm/yyyy
Time Zone
-12:00
-11:45
-11:30
-11:15
-11:00
to
-1:00
-0:45
-0:30
-0:15
0:00
+0:15
+0:30
+0:45
+1:00
to
+12:15
+12:30
+12:45
+13:00
Sets a time zone (Difference from
GMT).
(Sets in increments of 15 min. in the
range of -12:00 to +13:00.)
Daylight
Saving
On
Off
Sets the summer time to On/Off.
When setting to On, set the current time
forward one hour.
When setting to Off, set the current time
back one hour.