45530603TH Rev.2
5-32
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
BeLt=xxxx(***)
BELT: xxxx = Belt temperature [Unit: ˚C]
(***) = Belt thermistor scanning AD value [Unit: HEX]
tHicK=***um
MPt W=***mm
THICK --- Media Weight detection value [Unit: µm]
MPT W --- MPT Paper width detection value [Unit: mm]
<<Temperature and Humidity Sensor and Thermistor Range that can be displayed>>
Name
Range that can be displayed
Unit
Min
Max
Environmental humidity
0
99
%
Environmental temperature
0
60
˚C
Low-voltage power thermistor
0
140
˚C
Fuser unit center thermistor
0
300
˚C
Fuser unit heater thermistor
0
300
˚C
Fuser unit Lower thermistor
0
300
˚C
Fuser unit side thermistor
0
300
˚C
Belt thermistor
-20
120
˚C
5.3.2.6 Color registration adjustment test
The color registration adjustment test is used for adjusting color registration or investigating
the cause(s) of color misregistration.
Chapter 2 about description on color registration adjustment should be followed for recovery
from an error caused by the test.
1. Enter the self-diagnostic-mode(Level1) and, until the following message
appears, press the
MENU
or
MENU
button.
Reg aDJUst test
2. Press the
OK
button. The following message appears. Press the
MENU
or
MENU
button until the intended option appears.
Reg aDJUst test
Reg aDJ eXecUte
3. Press the
OK
button. The option displayed on the panel is performed:
<When the REG ADJ EXECUTE is performed>
①
Color registration adjustment test is performed, the lower line of the display
starts blinking.
②
When the test ends, the upper line of the display shows the result of the test (OK
or an error name), the lower line of the display shows ‘****RESULT’.
oK
Reg aDJ ResULt
Pressing the
MENU
button displays the next test result.
Pressing the
MENU
button displays the preceding test result.
Press the
BACK
button to return to step 2 (REG ADJ RESULT).
Remark:
The following message appears while the device is initialized or
issues an alarm or when the cover is open.
ng
Reg aDJ ResULt