45530603TH Rev.2
4-15
Oki Data CONFIDENTIAL
4. TROUBLESHOOTING PROCEDURE
LCD Status Message
( represents a blank line.)
Online
indicator
Inspection
lamp
Details
Error
code
Check Data
Message Data Write
Error <%CODE%>
Varies Varies Indicates that writing of the message
data for updating has failed.
%CODE% is a decimal value (single
digit) indicating cause of the writing
failure.
=1 FAIL Cause of the failure is unknown.
=2 DATA_ERROR Hash check error during
data read/write. FLASH error.
=3 OVERFLOW Download failure because
the FLASH capacity became full during
writing or reading the language file.
=4 MEMORY FULL Failed to secure
memory space.
=5 UNSUPPORTED_DATA Download of the
data that is not supported by the printer.
Error
(ONLINE)
Install Toner
For Maximum
Performance Always
Use %COMPANY_
NAME% Original
–
–
Only when ENABLE is set for the
pertinent printer setting, this error
message is displayed following the toner
empty error status message (Priority 334
or 334.5). The printer setting should be
made by PJL (OKIORIGINALCONSUMA
BLEDISPLAY=ON/OFF).
–
Wait a Moment
Rebooting
<%CODE%>
It may take some
time to complete this
process.
Off
On
Indicates that the controller unit is being
rebooted.
%CODE% is a decimal value (one digit)
indicating the cause of the reboot.
=0....Reboot that is resulted from a cause
other than the below.
=1....Reboot by the PJL command
=2....Reboot caused by the menu change
=3....Reboot based on quit operator of
PostScript Language
=4....Reboot caused by the network
utilities (including web)
Error
Shutting down
Please wait.
Printer will turn off
automatically
It may take some
time to complete this
process.
Off
Off
Indicates that the printer is shutting down.
The shut-down process is started by
holing down the power switch for four or
more seconds after the completion of the
printer initialization process.
Error
LCD Status Message
( represents a blank line.)
Online
indicator
Inspection
lamp
Details
Error
code
Turn off power
Shutdown completed
Off
Off
Indicates that the printer has completed
the shut-down process. (The LCD
backlight shuts off.)
* This status is displayed for a split
second at the instant preceding
automatic power shutoff. It is so brief
that the display can hardly be seen.
Error
Power Off and Wait
for a while
126:Condensing
Error
Off
Blink
Dew condensation error
(This error is handled in the same way
as the service call error though displayed
differently.)
Fatal
126
Service Call
nnn:Error
Off
Blink
Indicates that a fatal error has occurred.
For more information, see “Service Call
Error List”
* "Status Code" and "USTATUS
Message" can be acquired by MIB.
Fatal
<nnn>
Service Call
nnn:Error*
Off
Blink
Indicates that a fatal error has occurred.
For more information, see “Service Call
Error List”
"*" indicates the detailed error cause.
* "Status Code" and "USTATUS
Message" can be acquired by MIB.
Fatal
70
73
75
203
204
096
231
128
166
168
169
Power Off/On
nnn:Error
PC:nnnnnnnn
LR:nnnnnnnn
FR:nnnnnnnn
Varies Varies Indicates a fatal error has occurred.
for more information, see “Service Call
Error List”
"nnnnnnnn" indicates the detailed error
cause.
Fatal
002 ~
011
F0C
F0D
FFE
FFF
Power Off/On
209:Download Error
Off
Blink
Downloading Media Table to PU has failed.
(Related to Custom Media Type)
* "Status Code" and "USTATUS
Message" can be acquired by MIB.
Fatal
209