45530603TH Rev.2
6-22
Oki Data CONFIDENTIAL
6. REPLACEMENT OF PARTS
6.2.25 Low-Voltage-Power-Unit/Low-Voltage-FAN/
Geard-Motor
(1) Remove the Plate-Cover-MainPCB.(Refer to section 6.2.20)
(2) Remove the three screws(silver)(8mm)
①
and remove the Cover-Rear-Bottom
②
.
(3) Remove the twelve screws(silver)(6mm)
③
and remove the Board-Power-Assy
④
.
(4) Remove the six Round-head screw(black)(6mm)
⑤
and two screws(silver)(8mm)
⑥
and remove the AC-Inlet
⑦
and Low-Voltage-Power-Unit
⑧
.
(5) Remove the two screws(silver)(30mm)
⑨
and remove the FAN
⑩
.
(6) Remove the two screws(silver)(6mm)
⑪
and remove the FAN
⑫
.
Warning
Risk of Electric Shock
There is a risk of electric shock during replacement of the low voltage power supply.
Use insulating gloves or avoid direct contact with any conducting part of the
power supply, and caution should be exercised during replacement.
The capacitor may take one minute to complete discharge after the AC cable
is unplugged. Also, there is a possibility that the capacitor doesn’t discharge
because of a breakage of the PCB, etc., so remember the possibility of
electric shock to avoid electric shock.
6.2.26 Paper size sensor
(1) Remove the Cassette-Assy.(Refer to section 6.2.8)
(2) Remove the Board-Power-Assy.(Refer to section 6.2.25)
(3) Disconnect the connector.
(4) Remove the two claws and remove the Holder-PS-Switch
①
.
(5) Remove the paper size sensor
②
.
①
Claw
Claw
Claw
②
①
×3
⑥
×2
⑨
×2
⑪
×2
③
×12
⑤
⑤
⑤
⑤
⑤
②
⑧
⑩
⑫
⑦
④
Ⓐ
Ⓐ