45530603TH Rev.2
5-41
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
1. Enter the self-diagnostic-mode(Level1) and, until the following message
appears, press the
MENU
or
MENU
button.
MeDia Wt aDJUst Pa
2. Press the
OK
button. The following message appears. Press the
MENU
or
MENU
button until the intended option appears.
MeDia Wt aDJUst Pa
eDit tHicKness Data
3. Press the
OK
button. The test of the option displayed on the panel is performed.
<EDIT THICKNESS DATA is executed>
①
When the above step 3 is performed, the following message appears. Press the
MENU
or
MENU
button until the intended option appears.
saMPLe Page
②
By pressing the OK button while an item you wish to set is displayed, the option
can be set. Enter a value you wanted to set with the following SW operation.
saMPLe Page
P=*
Pressing the
MENU
button displays the next test result.
Pressing the
MENU
button displays the preceding test result.
③
Press the
BACK
button to return to the
①
.
④
Repeat the steps
①
to
③
as necessary.
<WEIGHT SCAN ADJ EXEC is performed>
①
The sensitivity adjustment of the media weight detection sensor starts and the
lower line of the display starts blinking.
②
When the sensitivity adjustment is completes, the upper line of the display
shows the result of the test (OK or an error name), the lower line of the display
shows ‘****RESULT’.
oK
WeigHt scan aDJ RsLt
Remark:
The following message appears while the printer is initialized or
issues an alarm or when the cover is open.
ng
WeigHt scan aDJ RsLt
Pressing the
MENU
button displays the next test result.
Pressing the
MENU
button displays the preceding test result.
Press the
BACK
button to return to step 2 (WEIGHT SCAN ADJ RSLT).
③
Pressing the
CANCEL
button during the test cancels the test, restoring the state
of step 2.
<WEIGHT SCAN ADJ RSLT is performed>
Same button operation as of WEIGHT SCAN ADJ EXEC.
4. Repeat steps 2 and 3 as necessary.
5. Press the
BACK
button to end the test (the state is restored to the step1).
MEDIA WT ADJUST PA Selection Items
SUB MENU
Details
Handling of results
EDIT THICKNESS
DATA
Number of sheets fed,
media weight setting
For displayed items, refer to the table
「
EDIT
THICKNESS DATA Selection Items
」
.
WEIGHT SCAN ADJ
EXEC
Execution of media
weight detection
mechanical adjustment
OK: Writes an adjustment value in EEPROM.
NG: Displays errors and updates RESULT
only.
WEIGHT SCAN ADJ
RSLT
Refer to the result of
media weight detection
mechanical adjustment.
For displayed items, refer to the table
「
WEIGHT SCAN ADJ RESULT
」
.