43856301TH Rev.3
69 /
Oki Data CONFIDENTIAL
4. Component replacement
Toner Sensor PCB
Front Sensor Cable
1st Paper end Cable
Hoppng Motor Cable
Solenoid Cable
Belt IDup Motor Cable
Option Cable
High voltage
Relay
Fuser Motor Cable
Low voltage Pow Unit
Hook on connector (230V)
AC
100V or 120V Plug On 230V UnPlug
Heater AC Cable
C-LED-HEAD
M-LED-HEAD
Y-LED-HEAD
K-LED-HEAD
Control Panel
ID-FAN cable
RFID cable
Stack full sensor cable
Controller PCB
ID Motor Cable
DCHEA
T
RELAY
POWER
OPTION
HVOLT
BELIDUP
CUIF
IDF
AN
HOPSIZE
FSNS
PE
STKFL
RFID
SSNS
DCID
OPE
POWFAN
HSOL
4.2.10 Top cover Assy
(1) Remove the left side cover. (See section 4.2.3)
(2) Remove the right side cover. (See section 4.2.4)
(3) Remove the rear cover. (See section 4.2.6)
(4) Remove the plate shield Assy (PLD/GDI) and take the control PCB out. (See
section 4.2.8 (1)-(7))
(5) Remove the connectors of the stack full sensor cable and ID-FAN cable, remove
the connector and the hanging RFID cable .
(6) Remove two E type stop rings and two torsion springs , and remove the top
cover Assy .