43856301TH Rev.3
141 /
Oki Data CONFIDENTIAL
7. Troubleshooting and repair procedure
Display on operator panel
ON
LINE
lamp
Inspection
lamp
Contents
Code nnn
Close the cover.
%ERRCODE%: Rear
cover is open.
Off
Blink
Indicates that the cover is open.
Error 316: Duplex unit cover.
Error
316
Wait for a while.
Data processing is in
progress.
Off
Blink
Indicates that reception of the NIC
program data for upgrading is in
progress.
Error
Wait for a while.
Data reception processing
is in progress.
Off
Off
Indicates that reception of the
NIC program data for upgrading is
complete.
Error
Check the data.
Received data error
<%DLCODE%>
Off
On
Indicates that an error has occurred
during reception of the NIC program
data for upgrading.
%DLCODE%
1: Size error
2: Checksum error
3: Printer model number error
4: Module I/F version error
5: FAT version error
Error
Wait for a while.
Data write is in progress.
Off
Blink
Indicates that writing of the NIC
program data for upgrading is in
progress.
Error
Restart the printer.
Data write is in progress.
Off
Off
Indicates that writing of the NIC
program data for upgrading is in
complete.
Error
Check the data.
Data write
error<%DLCODE%>
Off
On
Indicates that an error has occurred
during writing of the NIC program
data for upgrading.
%DLCODE%
1: Memory allocation error
2: Download file error
3: Device free space acquisition error
4: Device insufficient free space error
5: File write error
6: CU-F/W mismatch error
Error
Display on operator panel
ON
LINE
lamp
Inspection
lamp
Contents
Code nnn
Printer restart is in
progress %CODE%.
Off
On
Indicates the reboot of the controller
unit is progress.
%CODE% is a decimal value (single
digit) indicating cause of the reboot.
=0....Reboot that is resulted from a
cause other than the below.
=1....Reboot by the PJL command
=2....Reboot caused by the menu
change
=4....Reboot caused by the network
utilities (including web)
Error
Printer shut-down is in
progress.
Off
Off
Indicates that a printer is shutting
down.
The shut-down process is started by
pressing the BACK button for more
than 4 seconds upon completion of
printer initialization process.
Error
SHUTDOWN
Off
Off
Indicates that the shut-down process
of a printer is complete.
Error
PLEASE POW OFF
SHUTDOWN COMP
Off
Off
Indicates that the shut-down process
of a printer is complete.
(The LCD backlight turns off.)
Error
POWER OFF AND WAIT
FOR A WHILE
%ERRCODE%:
CONDENSING ERROR
Off
Blink
Dew condensation error (This error
is handled in the same way as the
service call error though display only
is different.)
*The Fatal Errors are not supported
by the various languages.
Fatal
126
POWER OFF/ON
%ERRCODE%:FATAL
ERROR
Off
Blink
Indicates that a fatal error has
occurred.
For detailed contents, refer to
"Service Calls List".
*The Fatal Errors are not supported
by the various languages.
Fatal
<nnn>
SERVICE CALL
%ERRCODE%:FATAL
ERROR
Off
Blink
Indicates that a fatal error has
occurred.
For detailed contents, refer to
"Service Calls List".
*The Fatal Errors are not supported
by the various languages.
Fatal
<nnn>