Effective April 2006
7
OG-75 Thru OG-750 Oxygen
Generator Specifications
Model
Oxygen Output
Air Required
Power
*SCF/Hour
**NM³/Hour SCF/Minute
NM³/Minute Watts/Hour
OG-75
75
2.0
17
0.45
120
OG-100
100
2.6
22
0.58
120
OG-175
175
4.6
32
0.84
120
OG-250
250
6.6
45
1.18
120
OG-375
375
9.9
68
1.78
120
OG-500
500
13.1
88
2.31
120
OG-650
650
17
118
3.10
120
OG-750
750
19.7
133
3.50
120
Model
Dimensions (D x W x H)
Weight
Inches
Centimeters
Pounds
Kilograms
OG-75
21 x 21.5 x 67
53 x 54 x 170
310
141
OG-100
24 x 24 x 69
61 x 61 x 175
500
227
OG-175
25 x 26 x 72
64 x 66 x 183
775
351
OG-250
26 x 32 x 72
66 x 81 x 183
1100
499
OG-375
30 x 36 x 84
76 x 91 x 213
1350
612
OG-500
36 x 48 x 83
91 x 122 x 211
1800
816
OG-650
48 x 55 x 83
122 x 140 x 211
2400
1625
OG-750
38 x 52 x 88
97 x 132 x 224
2600
10888
The Oxygen Purity Specification is 93% (
±
3%) for all models.
The Minimum Feed Air Pressure Required is 90 PSIG (621 kPa) for all models.
The Minimum Oxygen Pressure Delivered is 45 PSIG (310 kPa) for all models.
For domestic models the Power Configuration is 110 VAC/60 Hz, for export models 220
VAC/50 Hz.
* - A Standard Cubic Foot (SCF) is a cubic foot of gas at 14.7 psia (sea level atmospheric pressure) and 60 degrees
Fahrenheit
** - A Normal Cubic Meter (NM
3
) is a cubic meter of gas at 760 mm-Hg (sea level atmospheric pressure) and 0
degrees Celsius
Summary of Contents for OG-75
Page 15: ...Effective April 2006 12 Sieve Re packing Diagram...
Page 26: ...Effective April 2006 23 Process Flow Schematic...
Page 27: ...Effective April 2006 24 Process Flow Schematic Touchscreen Option...
Page 29: ...Effective April 2006 26 External Components Drawing 22 G G 22...
Page 33: ...Effective April 2006 30 Internal Components Drawing SMC SMC Direct 05 LOGIC Koyo SMC...