83
OETIKER EPC 01
aPPenDIX
Issue 11.22
08905306
13 2 2 Interface X1 pincer
Parameter
Value / Description
Designation
X1
Type
Interface consists of 2 connections:
•
D-sub 9-pin for electrical connection, D-sUb connector with screw restraint
•
Plug-in connection for compressed air output pa
Usage
Connection of the hybrid hose
13 2 3 X12 interface jack
Parameter
Value / Description
Designation
X12
Type
Jack socket for 3.5 mm jack plug
Usage
Read out the following data in test mode:
•
Traveled path in the pincer (not at the pincer head)
•
Pincer pressure curve
Cable specification
suitable cable available from oeTIKeR
13 2 4 X20 interface digital connection
General technical data
Parameter
Value / Description
Designation
X20
Type
25-pin D-sUb plug with screw restraint
Usage
Connection for external control
Cable specification
•
shielded cable required
•
Cable length ≤ 3 m
Inputs and outputs
The opto-decoupled inputs and outputs are supplied by the customer.
Inputs
Outputs
Parameter
Value / Description
Parameter
Value / Description
Pin 1
24 V ± 10%
Pin 1
24 V ± 10%
Pin 25
GnD
Pin 25
GnD
signal
0
0 to 5 V
signal
0
0 V
signal
1
15 to 26.4 V
signal
1
-0.5 V
Input current
10 ma (at 24 V)
output current