75
OETIKER EPC 01
TRoUblesHooTInG anD eRRoR MessaGes
Issue 11.22
08905306
Error message
Cause of the error
Troubleshooting measures
PE7004
for the
Force priority
closure func-
tion, the closure force and closure
gap are outside the tolerance range:
•
The pincer jaws have slipped off
the clamp.
•
Clamp is broken.
•
The pincer is not correctly posi-
tioned on the clamp (pincer jaws
parallel to clamping strap)
•
no clamp inserted
•
The part being clamped is not
inserted
Perform actions in the following sequence until the
error is eliminated:
►
If the clamp is broken or the pincer jaws have
slipped, repeat closure using a new clamp.
►
Insert correct clamp and the parts being clamped.
►
Position the pincer correctly: perpendicular to the
part being crimped.
►
extend closing time.
for the
Gap priority
closure function,
the closure force and closure gap are
outside the tolerance range:
•
The pincer jaws have slipped off
the clamp.
•
Clamp is broken.
•
no clamp inserted
•
The part being clamped is not
inserted
•
In order to reach the pre-set
closing gap more than the pre-
set closing force is required
•
The closure force setting is
outside the pincer head specifi-
cation
Perform actions in the following sequence until the
error is eliminated:
►
If the clamp is broken or the pincer jaws have
slipped, repeat closure using a new clamp.
►
Insert correct clamp and the parts being clamped.
►
extend closing time.
►
Proceed with the pincer test.
►
Check the type of clamp.
PE7005
The holding force is outside the toler-
ance range:
•
The holding tolerances selected
are too tight
•
Holding force selected is too low
Perform actions in the following sequence until the
error is eliminated:
►
Increase the holding force tolerance.
►
Increase the holding force.
PE7006
The holding force is outside the toler-
ance range:
•
a wrong clamp was closed
(not suitable for this aPn)
•
The pincer jaws have slipped off
the clamp.
•
While holding, the clamp was
deformed
Perform actions in the following sequence until the
error is eliminated:
►
Insert the correct clamp.
►
Check the holding force and reduce it if neces-
sary.
►
Proceed with the pincer test.
►
Check the holding gap tolerances and increase
them if necessary.
PE7007
The holding force and holding gap
are outside the tolerance range:
•
no clamp inserted
Perform actions in the following sequence until the
error is eliminated:
►
Insert the correct clamp.
►
Proceed with the pincer test.
►
Check the holding force and holding gap toler-
ances and increase them if necessary.