29
OETIKER EPC 01
sTRUCTURe anD ConneCTIon
Issue 11.22
08905306
5 3 Initial commissioning
9
ePC 01 set up and connected.
9
Documents supplied with licensing code.
1. start the PC-software on the PC.
2. switch on Control Unit. acknowledge error, if present.
3. Connect PC to an interface of Control Unit (e.g. Usb).
4. In the PC-software, navigate to menu page
Home > Control Unit >
Connect to Control Unit
.
5. select correct interface (e.g. Usb).
6. Press
Connect
button.
7. log in as Customer admin.
8. navigate to the menu page
Home > Control Unit >
Commands > Control Unit Licensing
.
9. enter the license code provided with your documentation
in the input field.
10. Press
Send
.
The transfer is successful if the connection is interrupted
and the connection view is displayed.
11. Reconnect Control Unit to PC-software.
12. navigate to the menu page
Home > Control Unit > Read
13. select
Create new local data set
.
14. enter a name for the data set in the input field.
15. Press
Read
.
16. Configure database with desired settings and send to
Control Unit.