27
OETIKER EPC 01
sTRUCTURe anD ConneCTIon
Issue 11.22
08905306
Pincer and hybrid hose
CAUTION
Damage to the pincer and the hybrid hose due to improper assembly!
►
Do not clamp the pincer at the cylinder tube of the pincer body (only the Ho 7000 version
can be clamped at the reinforced point at the center of the pincer body).
►
Do not strike the pincer and do not allow it to be dropped.
►
Do not lift and transport the pincer using the hybrid hose.
►
Comply with the maximum permissible bending radius of 50 mm of the hybrid hose; do not
bend it to a tighter radius.
►
after assembly, clamp the pincer in the pincer holder.
4. Using the hybrid hose (3), connect the pincer (2) on the underside of the Control Unit (4):
–
Connect the electrical plug of the hybrid hose to the connector
X1
. secure the plug-in connection
finger-tight with both screws.
–
Connect the pneumatic plug of the hybrid hose to the compressed air outlet
pA
.
5. Mount the pincer holder (1).
6. secure the pincer (2) in the pincer holder (1) or optionally suspend it from the suspension bracket.
PC and PLC (option)
7. If required, connect the PC (10) or a PlC to the interfaces of the Control Unit (4).
Components of the compressed air supply
WARNING
Escaping compressed air!
In the event of improper work on the compressed air supply, escaping flows of compressed air
can lead to injuries.
►
Permit only qualified personnel to work on the compressed air supply.
►
ensure that the compressed air supply is disconnected.
1. Mount the compressed air filter (7):
–
fasten the mounting bracket of the compressed air filter close to the Control Unit.
–
Mount the compressed air filter suspended on the mounting bracket (the filter insert points downwards).
2. Mount the compressed air tank (8) upstream from the compressed air filter (7) and connect it to the com-
pressed air filter.
3. Mount the service unit (9) upstream from the compressed air reservoir (8) and connect it to the compressed
air reservoir.
4. Connect the safety shut-off valve (6) to the compressed air filter (7).
5. Connect the compressed air supply line (5) to the safety shut-off valve (6).
6. Connect the compressed air supply line (5) to the compressed air inlet
pE
on the top of the Control Unit (4).
7. Check all connections for a tight fit and tighten them if necessary.
8. Connect the service unit (9) to the compressed air supply/compressor (12) using a suitable hose.