The firmware time of the Control Unit can deviate up to 6 minutes per day. Therefore, regular time
synchronization is recommended for data storage.
If an nTP server is used, it must be included in the same network as the Control Unit
Editing clamping settings
navigation:
Home > Local data set > Settings Control Unit > Closing
The following
General closing settings
are made on the
Closing
sub-menu page:
Element
Description of the setting
Start
(Type of
triggering)
select the type of triggering.
•
START
button on the triggering unit
•
external control: If the start signal is sent from a external control, this must be selected
here. With this option, the safety valve must be actively mechanically locked by a lock-
ing ring recommended by oeTIKeR (
).
•
START
button on the Trigger Unit and external control jointly
Input control
select the source of the start signal.
•
Control Unit: operation via the Rotary pushbutton
•
X20: operation via digital signals of the X20
•
Industrial network: operation via the selected bus system (ethernetIP, etherCaT,
Profinet)
Fig 41:
Closure sub-menu