Clamp pincer CP 10 / CP 20 / CC 20
8 Appendix
Issue 06.19
08902961
8-49
8
Appendix
8.1
General information in event of faults
If the closure operation of clamp pincer CP 10 / CP 20 / CC 20 does not start or does not operate correctly,
consult maintenance personnel responsible for clamp pincer CP 10 / CP 20 / CC 20.
8.2
Reaction in event of faults
If a fault occurs, the clamp pincer will be blocked. The service LED will light up red or orange. Operation can be
restarted only by briefly removing the battery and reinserting it ("reset").
If after the clamp pincer have been “reset” the fault is still present, contact your OETIKER contact person.
8.3
Error messages and troubleshooting measures
INFO
Closure-relevant error messages can be read out with PC software (individual or multiple report).
Please send the respective reports to your OETIKER contact person.
Service LED
Fig. 38: Service LED
Display after the pressing operation
Cause / remedy
lights up green
Closure force OK.
flashes green/red
Closure force OK, service interval exceeded.
Have the device serviced.
lights up red
Closure force
incorrect
or hardware error
Recalibrate the device. Repeat the joint. Contact the
Service Center if necessary.
lights up orange
Temperature error.
Warm up the tool or cool it down.