The values of the closure data set are automatically
adopted by the PC software and loaded into the input
fields.
3.
Click on the “Send data to device” button.
The data is confirmed and transmitted to the clamp
pincer. The status bar shows the progress of data
transmission.
INFO
After every change to the target closure force, the clamp pincer must be calibrated.
Save the input values and calibrate the clamp pincer.
5.1.3
Calibrating clamp pincer
NOTE
Possible damage to the clamp pincer and faulty clamp closures!
To ensure uniform and reproducible process quality calibration must be executed at least once per shift or
once per day. Calibration is also necessary if any pincer components are exchanged. OETIKER recommends
checking the closure force after calibration as an additional verification measure. It is critical to ensure that
clamps are not closed in calibration mode.
Requirement:
The clamp pincer must be connected to the PC via the USB cable.
The calibration gauge is fitted with appropriate gauge jaws for the respective pincer head.
The new closure force value has been transmitted to the clamp pincer so that it is automatically
incorporated into the pincer test.
1.
Click the “Start calibration” button in the
Calibration menu.