Clamp pincer CP 10 / CP 20 / CC 20
5 Use of the clamp pincer
Issue 06.19
08902961
5-25
The “Calibration finished” window now opens.
This displays the calculated correlation factor
(Cal.) (ratio between the thrust force of the
plunger and the closure force of the pincer jaws)
for information purposes.
NOTE
For safety reasons, there is a minimum and maximum calculated correlation factor (Cal.), and an error
message appears if it is either not met, or surpassed. In such event, the calibration must be repeated.
4.
Click on the “OK” button.
The pincer test is completed and the PC software changes to the "Status" tab start screen see chapter 7.2, p. 7-
41.
5.2
Working with clamp pincer CP 10 / CP 20 / CC 20
5.2.1
Displaying the battery charge status
The battery charge level is displayed on the battery charger LED (see also chapter 8.3, p. 8-49). It can also be
read directly off the battery.
Fig. 9:
Checking the battery charge level
Press button (Fig. 9/2).
The number of illuminated LEDs (Fig. 9/1) shows the charge status. A flashing LED indicates less than 10 %
charge level.