Clamp pincer CP 10 / CP 20 / CC 20
7 Description of PC software
Issue 06.19
08902961
7-41
7.2
Status menu
•
Display of the closure force curve (progression of the closure force over time) of the most recent closure or
any selected closure.
•
Display of the process data for the most recent closure or any selected closure.
Fig. 32: Status menu
Input field/Display field/Option
field
Description
Closure force
The graphic displays the progression of the closure force over time for the
selected closure operation. When closure has been performed correctly,
the summit of the curve must lie within the green shaded area.
If this is not the case, contact your service partner without delay.
Comment
For input of user-defined texts (maximum 10 lines). The comments refer
to the selected closure operation and are included in the single report for
that closure, but not in the multiple report (see below for an explanation).
The text is not saved in the device.
Single report / Multiple report
The closure force diagram for a closure operation, together with other
process data, can be called up by pressing the buttons “Single report”
(documentation of
an individual closure operation) or “Multiple report”
(collective documentation of several closure operations).