Clamp pincer CP 10 / CP 20 / CC 20
5 Use of the clamp pincer
Issue 06.19
08902961
5-23
2. In the Confirmation menu, click on OK to confirm.
Initial calibration
The “Calibration/Initial calibration” window now
opens.
The initial closure force has already been input and
doesn’t need to be re-entered.
3.
Click on the “Start initial calibration” button.
The “Initial calibration” information window
opens. This describes the next steps and
contains a counter showing the number of
measurement closures.
Once the measurement closure has been
performed the “Initial calibration” window closes
automatically.
4.
Input the measured value into the “Measured
value [N]” field.
The “Send measured value to device” button
lights up green.
5.
Click on the “Send measured value to device”
button.
The measured value is acknowledged and sent
to the device.