DIAM3100©2012 AUGIER SA.
VI-57
VI
APPENDIX B: JBUS TABLE
Adr. R/W Mode
Memory Label
Detail
Bit clear
Bit set
Default
Value
Comments
0
R
Ram
Warnings
Bit0
Stop
Start
0
Main switch status
Bit1
OK
Pb power line
0
Power supply over range
Bit2
OK
Pb EFD
0
Level 1 or Level 2 or EFD board
defect
Bit3
OK
Pb current
0
Open circuit or Over current or
Regulation error
Bit4
OK
Pb regul
0
Regulation error
Bit5
OK
Pb open circuit
0
Open circuit
Bit6
OK
Pb Overcurrent
0
Over current
Bit7
Local or Stop
Remote control
Bit 7:8, 0:0 = Local , 0:1 = Stop,
1:0 = Remote
Bit8
Local or Remote
Stop mode
Bit9
OK
EFD level 1 warning
0
Earth fault detect (OPTION)
Bit10
OK
EFD level 2 warning
0
Earth fault detect (OPTION)
Bit11
OK
LFD level 1 warning
0
Lamp fault detect (OPTION)
Bit12
OK
LFD level 2 warning
0
Lamp fault detect (OPTION)
Bit13
OK
Internal failure
0
CCR internal problem
1
R
Ram
Brightness back indication
0 : Stop
1 : Brightness B1
2 : Brightness B2
3 : Brightness B3
4 : Brightness B4
5 : Brightness B5
6 : Brightness B6
7 : Brightness B7
8 : Brightness B0 (Heat)
2
R
Ram
Io loop current
*10mA
3
R
Ram
U injection EFD
500
*V
4
R
Ram
Uo loop voltage
*V
5
6
R
Ram
Mains voltage Ui
*V
7
R
Ram
Mains current Ii
*A (OPTION)
8
R
Ram
Output power Po
*VA
9
10
R
Ram
EFD Resistance
*KOhms (1..65000)
11
R
Ram
Number of burnt lamps
12
R
Ram
Open load ratio measurement
*%
Summary of Contents for AUGIER energy DIAM3100 Series