DIAM3100©2012 AUGIER SA.
I-16
I.3.3 GENERAL ELECTRICAL FEATURES
•
Power supply voltage
:
Single phase: 220, 230, 240, 380, 400 or 415 Vac, +/-10% (IEC), 50 Hz
5%.
•
Maximum rated current
: 6.6 A
•
Number of Brightness Levels:
maximum 8, adjustable.
•
Heating Brightness (“Black current”):
The CCR can produce “heating” level brightness at low current (1.8A preferred), which is used to
remove condensation from the interior of the lamp lenses without lighting up their bulb. The symbol for
local setting is ‘B0’.
•
Remote Control:
serial network, Ethernet (Modbus/TCP), souriau connectors
•
Output power:
1KVA, 2.5KVA, 4KVA, 5KVA or 6.5 KVA.
•
Power factor:
> 90%
•
Efficiency :
> 90% at nominal voltage and rated resistive load.
•
Output Current Regulation:
Better than
100mA under the following conditions: Power supply voltage
–10/+10%, Frequency:
5%,
Load: from 0 to 100%
•
Load adaptation
:
The output transformer is equipped with adjustment taps in order to adapt the rated output voltage of
the CCR to the present load. Six terminals allow load adaptation with steps of 12.5%.
•
Protection:
The electronic circuitry is protected against fluctuations by the use of a Hall effect sensor for current
measurement, and fibre optics for thyristors control. Electronic board manages all overcurrent, open
circuit or mains under/over voltage.
•
LV Protection
:
A set of power fuses, a set of fuses for auxiliaries power supply
, and “glass” fuses on the circuit boards
provide LV protection.
•
Lightning arrestors
:
These regulators are provided with output lightning arrestors.
Summary of Contents for AUGIER energy DIAM3100 Series
Page 2: ...DIAM3100 2012 AUGIER SA I 2...
Page 6: ...DIAM3100 2012 AUGIER SA I 6...
Page 13: ...DIAM3100 2012 AUGIER SA I 13 I 2 4 DIMENSIONS...
Page 14: ...DIAM3100 2012 AUGIER SA I 14 Stacked CCRs...
Page 28: ...DIAM3100 2012 AUGIER SA I 28...
Page 56: ...DIAM3100 2012 AUGIER SA V 56 V APPENDIX A DIAGRAM...