Limits Due to Cell Voltage Scan Rate
The following are approximate cell voltage scan rates for different lengths of Cell Interface daisy
chains where all cells are installed. On the Stack Switchgear, the Measurement Anti-Aliasing Filter is
set to OFF.
Table 31. Cell Voltage Scan Rates for CI-16 and CI-4M12
Measurement Anti-Aliasing Filter
Cell Interface Chain Length
Scan Rate [Hz]
Off
1
5.53
Off
5
3.32
Off
10
2.22
Off
15
1.74
Off
20
1.38
Off
25
1.15
Off
30
0.91
Table 32. Cell Voltage Scan Rates for CI-12
Measurement Anti-Aliasing Filter
Cell Interface Chain Length
Scan Rate [Hz]
Off
1
6.01
Off
5
3.94
Off
10
3.03
Off
15
2.59
Off
20
1.97
Off
25
1.63
Off
30
1.44
Off
35
1.30
Off
40
1.08
Nuvation Energy High-Voltage BMS - Product Manual
Document ID: NE-PM-003
97
Rev 1.2, 2021-03-03
Curie Update 1