![Nuova Simonelli microbar ii Service Manual Download Page 70](http://html.mh-extra.com/html/nuova-simonelli/microbar-ii/microbar-ii_service-manual_1717952070.webp)
Edition 00 to 01/2018
8.2
SERVICE MANUAL
8.1
HOW TO ACCESS
1
Make sure the machine is turned OFF. Using a
Allen key, unscrew the four screws at the top
and remove the right and rear panel.
Take care to disconnect the ground connection
of the panels.
2
The electrical components are:
A
Strain relief for power cable entry point.
B
Ground connection.
C
Main switch.
D
Microswitch for drawer presence.
E
Grinder capacitor.
F
Grinder connector.
G
Power transformer for control unit and
group motor.
H
Electric control unit.
I
Microswitch for tank presence.
1
I
A
B
G
H
C
E
F
D