12.3.18
COFFEE LOWER TEMP.
1
From the service engineer mode menu, press
the
key to select "COFFEE LOWER TEMP."
and press ENTER
key to open the sub-
menu.
This setting allow to enable or disable the visu-
alization of the "MACHINE READY" slightly ear-
lier than the effective temperature is reached.
2
Use
the -
keys to increase or decrease
the temperature.
NOTE
The max. temperature that can be set is 105°C
(221°F).
3
Press key to return to previous menu, with
the confirmation of the value set.
Edition 00 to 01/2018
12.23
SERVICE MANUAL
Coffee Lower Temp.
0090
o
C 0194
o
F
Coffee Lower Temp.
0086
o
C 0187
o
F
Coffee Lower Temp.
Summary of Contents for microbar ii
Page 1: ...SERVICE MANUAL ...
Page 2: ...Edition Date Changes on last versions 00 01 2018 Edition 00 to 01 2018 2 SERVICE MANUAL ...
Page 4: ......
Page 54: ...Edition 00 to 01 2018 5 6 SERVICE MANUAL ...
Page 62: ...Edition 00 to 01 2018 6 8 SERVICE MANUAL ...
Page 84: ...Edition 00 to 01 2018 10 4 SERVICE MANUAL ...
Page 90: ...Edition 00 to 01 2018 11 6 SERVICE MANUAL ...
Page 130: ...Edition 00 to 01 2018 13 8 SERVICE MANUAL ...
Page 136: ...Edition 00 to 01 2018 14 6 SERVICE MANUAL ...
Page 143: ...Edition 00 to 01 2018 16 1 SERVICE MANUAL 16 BEVERAGE PREPARATION 16 ...
Page 156: ...Edition 00 to 01 2018 18 6 SERVICE MANUAL 18 6 DISPLAY CONTRAST ADJUSTMENT ...
Page 170: ...Edition 00 to 01 2018 19 14 SERVICE MANUAL ...
Page 171: ......