WATER HARDNESS SETTING:
A
When the display show the message "Water
Hardness °Fr" press ENTER
key to access
the function.
B
Press -
keys to increase or decrease the
water hardness.
Than,
press
ENTER key to save the data set
and return to previous menu, or press RESET
key to return to the previous menu without
saving the data.
The table shows the correspondence between the
hardness set and the used water litres, above which
the message "
CARRY OUT DECALCIFICATION
".
WATER HARDNESS °FR
WATER LITRES
1-7
1500
8-30
1000
31
500
00
Alarm disabled
Edition 00 to 01/2018
12.29
SERVICE MANUAL
NOTE
The alarm "CARRY OUT DECALCIFICATION" does
not interrupt the machine functioning and is
reset after having carried out the decalcification
cycle together with the litre counter. When the
value set is "00", the alarm is deactivated.
Water Hardness
o
Fr
Water Hardness
o
Fr
00
Summary of Contents for microbar ii
Page 1: ...SERVICE MANUAL ...
Page 2: ...Edition Date Changes on last versions 00 01 2018 Edition 00 to 01 2018 2 SERVICE MANUAL ...
Page 4: ......
Page 54: ...Edition 00 to 01 2018 5 6 SERVICE MANUAL ...
Page 62: ...Edition 00 to 01 2018 6 8 SERVICE MANUAL ...
Page 84: ...Edition 00 to 01 2018 10 4 SERVICE MANUAL ...
Page 90: ...Edition 00 to 01 2018 11 6 SERVICE MANUAL ...
Page 130: ...Edition 00 to 01 2018 13 8 SERVICE MANUAL ...
Page 136: ...Edition 00 to 01 2018 14 6 SERVICE MANUAL ...
Page 143: ...Edition 00 to 01 2018 16 1 SERVICE MANUAL 16 BEVERAGE PREPARATION 16 ...
Page 156: ...Edition 00 to 01 2018 18 6 SERVICE MANUAL 18 6 DISPLAY CONTRAST ADJUSTMENT ...
Page 170: ...Edition 00 to 01 2018 19 14 SERVICE MANUAL ...
Page 171: ......