![Nuova Simonelli microbar ii Service Manual Download Page 35](http://html.mh-extra.com/html/nuova-simonelli/microbar-ii/microbar-ii_service-manual_1717952035.webp)
Edition 00 to 01/2018
3.9
SERVICE MANUAL
3.7
BLADE EJECTOR
WORM SCREW AND
BLADE EJECTOR REMOVAL
The blade ejector worm screw is located on the
lower support bracket of the group.
1
Once the pouring group has been removed; it
is possible to take out the blade ejector worm
screw by removing the two screws on the base
with a Phillips screwdriver.
2
To remove the blade ejector, it is necessary to
undo the screw with a 3 mm Allen wrench.
When refitting, the engineer will have to:
4
Reposition the shaft.
5
Pre-load the spring by one turn using the blade.
3
Gently turn the blade to free it from the shaft
and infusion chamber.
1
1
2
3
4
4
5
Summary of Contents for microbar ii