14.2
MACHINE BLOCK ALARM MESSAGES
DISPLAY INDICATION
CAUSE
EFFECT
SOLUTION
UPPER PISTON MOTOR
GROUP ALARM
Xxxxxx
Group Error
During the group
handling phase,
the upper piston
exceeded maxi-
mum set time by
10 seconds before
recognizing
motor pickup.
The control unit will
halt whatever cycle
is on by turning off
both the movement
actuator and those
for drink delivery;
the operator will
not be able to make
selections on the key-
board.
Open and close the machine door.
If the alarm reappears for a second
time, call the Service Technician.
HEATER FILLING ALARM
Xxxxxx
Boiler Filling
The heater filling
stage has exceed-
ed the 3 minute
maximum time;
the probe level is
uncovered.
The machine will
stop.
Contact the Service Technician.
TURBINE ALARM
Once having detected the
alarm, on the display, the
control unit alternates
the message relative to
the current beverage with
the error message con-
cerning such function. For
instance:
Flowmeter Error
The volume coun-
ter will not send
any impulses to
the control unit
for 5 seconds.
The delivery will
continue for up to 60
seconds or for as long
as any of the coffee
based drink keys are
pressed.
Open and close the machine door.
The control unit will repeat the
machine starting up procedure.
In case the alarm persists, the
machine can be used as a manual
appliance.
ȗ
Press the selected key to start the
dosing;
ȗ
Once the desired dose has been
delivered in the cup, press the
same key to halt the dose being
delivered.
Call the Service Technician.
WATER TANK EMPTY
ALARM
Refill Water Tank
The water tank is
empty.
The coffee will not
be delivered and the
dosing will be halted
while in progress.
Fill the water tank.
Use the Hot Water key to eliminate
any air bubbles.
CLEANING FILTER ALARM
Water Filter l.
20
The volume coun-
ter has reached
the number of
litres of deliver-
able water set
during program-
ming phase.
Coffee will not be
delivered; the dose
will not be halted or
it is variable.
Regenerate cleaning filter salts.
To erase the alarm see paragraph
on ‘RESETTING CLEANING FILTER
LITRE COUNTER’.
This alarm blocks all deliveries.
The cleaning filter alarm can be
eliminated by programming the
number of litres to zero (see para-
graph on ‘PROGRAMMING’).
Edition 00 to 01/2018
14.4
SERVICE MANUAL
Summary of Contents for microbar ii
Page 1: ...SERVICE MANUAL ...
Page 2: ...Edition Date Changes on last versions 00 01 2018 Edition 00 to 01 2018 2 SERVICE MANUAL ...
Page 4: ......
Page 54: ...Edition 00 to 01 2018 5 6 SERVICE MANUAL ...
Page 62: ...Edition 00 to 01 2018 6 8 SERVICE MANUAL ...
Page 84: ...Edition 00 to 01 2018 10 4 SERVICE MANUAL ...
Page 90: ...Edition 00 to 01 2018 11 6 SERVICE MANUAL ...
Page 130: ...Edition 00 to 01 2018 13 8 SERVICE MANUAL ...
Page 136: ...Edition 00 to 01 2018 14 6 SERVICE MANUAL ...
Page 143: ...Edition 00 to 01 2018 16 1 SERVICE MANUAL 16 BEVERAGE PREPARATION 16 ...
Page 156: ...Edition 00 to 01 2018 18 6 SERVICE MANUAL 18 6 DISPLAY CONTRAST ADJUSTMENT ...
Page 170: ...Edition 00 to 01 2018 19 14 SERVICE MANUAL ...
Page 171: ......