![Nuova Simonelli microbar ii Service Manual Download Page 58](http://html.mh-extra.com/html/nuova-simonelli/microbar-ii/microbar-ii_service-manual_1717952058.webp)
Edition 00 to 01/2018
6.4
SERVICE MANUAL
5
To replace the thermal fuse:
A
Turn off the machine and unplug it.
B
Disconnect the fuse connections and slide
out the fuse from the bottom. This opera-
tion takes place in the bottom part of the
boiler tank.
6.2
DRAINING THE BOILER
To empty the coffee boiler tank, the engineer needs
to: open the drain plug with the machine switched
off and once the boiler tanks are cool.
1
Remove the left side panel by undoing the 2
Allen screws.
2
Open the drain with a 14 mm wrench and
remove the inlet Teflon pipe.
Insert the pipe in a fitting to avoid water leaks.
Fig. 133
Fig. 134
B
2
1
A