2.3.2
MILK TEMPERATURE ADJUSTMENT
1
Insert the regulator on the pipe and adjust the
screw on the right hand side of the machine.
2
The default setting is to screen it completely
closed, then open by two and a half turns.
3
Turn the screw counter clockwise to increase
the flow, lowering the temperature, or clock-
wise to decrease the flow and increase the tem-
perature.
Edition 00 to 01/2018
2.11
SERVICE MANUAL
2
3
1