DSP LASER AP with MCS
Intervention of the Safety functions on the machine states
Every safety function, when activated, inhibits some phases of the machine cycle. The
following table reports the action of the function on the cycle phases.
Safety Function
High
Speed
Low
Speed
Upstroke
Front Protection (DSP LASER AP)
X
-
-
Downstroke Pedal Control
X
X
-
Antipanic
X
X
-
Emergency
X
X
-
One side guard
X
-
-
Both side guards
X
X
X
Rear guard
X
X
X
Upper and Lower Grippers
X
X
-
Low Speed Value Control
X
X
-
High Speed Value Control
X
X
-
Direction Control
X
X
X
Encoder Control
X
X
X
Stop Distance Verification
X
-
-
Misalignment Control
X
X
-
The symbol X in the table means that the intervention of the safety function inhinits the relevant cycle
phase.
The symbol – means that the intervention of the safety function has no effect on the relevant cycle
phase.
Residual
Risk
:
The device cannot detect the cross short circuit of the outputs. For this
reason, it is necessary, via wiring, to forbid the cross short circuit
towards other outputs or the short circuit towards other supplies.
DLAM01EN
53