Replacement method of fuses
Refer to P.53 for the applicable fuses.
1. The main power supply (main breaker) to which the
controller is connected is turned off, and energizing
to the controller is stopped.
2. The cause due to which the fuse is cut is investigated, and proper measures are given.
3. Remove fixing screws on terminal cover and then remove the cover. (Refer to P .11)
4. The cap comes out a little forward when twisting the cap of the fuse holder (Refer to P .6) upper the electric
power terminal board counterclockwise by 90° while lightly pushing it to the interior, and pull out the cap as it
is.
5. The fuse (cartridge) comes out with the cap too, then remove the fuse from the cap.
6. Please push a new fuse of the same rating as the broken fuse (confirm the current rating/voltage etc.) into the
cap. Please dispose of the broken fuse in an appropriate manner.
7. Insert the cap and the cartridge into the fuse holder, and twist the cap clockwise by 90 degrees with pushing it
to the interior to lock. Since the position (direction of the rotation) in which the cap enters is decided, do not
push it forcibly.)
8. Put back the terminal cover as original state and fix it with screws.
9. After safety is confirmed, the main power supply (main breaker) is turned on.
Warning
The power supply must always be turned off
and the engineer must work when replacing
fuses.
MIN
MAX
JAPAN
AC200-230V 50/60Hz 12A
V.F. CONTROLLER
RUN
Vib.A
LIMIT
RoHS
162
142
180
141
116
23
15
6
7
17
0
37
116
6.5
2-
φ
7
18
0
冷却ファン
2
2
P1
398
NTN
26
5
13
ケーブル
2-φ3.5
4
P1398
NTN
15
18
10
Cable
※
This figure is just for reference. Details of part layout
may be different from those of the actual product.
Please refer to P.7 also for installation.
※
Vibration sensor is an option part. Purchase it
separately.
Refer to P.14~P.15 for installation of vibration
sensor. Moreover, refer to directions of vibration
sensor for the specification of vibration sensor.