35
⑥
Press the data key, and write the data.
It returns to the function No. display.
*1
※
When 1 is selected by the function J10, it returns the normal
screen. (Refer to the boxed article below)
*2
※
When 3 is selected by the function J05, it enters to the
calibration work and after the calibration ends, it returns to the
normal screen.
※
Please return to
③
when you want to change other
functions in the same group.
Please press the function key when you
change other function
groups. The function group selection screen appears, then
operate from
②
again.
⑦
Please return to the normal screen by pressing the function key
twice (once for the function group selection screen) when the
change ended.
*
1
Please note that it returns to the normal screen without changing data when you press the function
key without pressing the data key after the data has changed at
⑤
.
*
2
Only when the function J10 is set to 1, it returns to the normal screen at the same time with resetting
all data to the values at factory shipment. At this time, there is a possibility of beginning driving if
there is a driving signal from the outside by any chance. Therefore turn OFF the control signal from
the outside before resetting it. Moreover, when you rewrite the data of the functions J00 and J10,
please press the stop key and UP or Down keys simultaneously. It cannot be changed with one key
pressed.
Stop key and UP key: Data up (0 => 1)
Stop key and Down key: Data down (1 => 0)
*
3
In case that it is difficult to cut off the external control input when function data which cannot be
changed during driving is changed, select the panel control (data 2 or 3) with driving method
selection J02. (It stops with the selection).
*
4 Please note that the data of H23 can not changed unless J06 is 0.
FUNC
RESET
DATA
ENTER