23
8. Driving and adjustment
Description of the operation panel
Outline of key operation
Key
(
Nominal name
)
Short press
(
less than 2 seconds
)
Long press (2 seconds or longer)
FUNC/RESET
(
Function
)
Return from various modes to normal mode (normal
screen). Reset of emergency signal at abnormal state.
Shift from normal mode (normal
screen) to function mode
DATA/ENTER
(
Data
)
Shift and return from normal mode (normal screen) or
operation lock mode to data display mode.
When data is changed, data is decided.
Shift from normal mode (normal
screen) to knob lock mode and
return
UP
[
Upward arrow
]
(UP
)
Increment of each function and data
(sending in order)
-
DOWN
[
downward
arrow
]
(DN or Down
)
Decrement of each function and data
(sending backward)
-
RUN /JOG
(
Run
)
Instruction of beginning of driving when selected on
the operation panel. When the JOG function is
selected, driving continues while it is pressing.
-
STOP
(
Stop
)
Instruction of stopping of driving when selected on the
operation panel.
-
STOP
+
UP (DN)
In case when the data of J00 and J10 are changed
-
UP
+
DN
It shifts to the data transfer mode.
-
№
Name of each portion
Description
A
Data display portion
(LED)
LED of 7 seg 4 digits. Monitoring of various
kinds of data, display of setting, warning etc.
B
Pilot lamp
Pilot lamp lights when controller is in
outputting (driving) state.
C
Function key
(Reset key)
Switching to function setting mode and return,
reset of emergency
D
Data key
(Enter key)
Setting of data, switching of monitor content,
setting of knob lock function
E
UP/DN key
(Up/Down key)
Up/Down of function and data when data
setting
F
RUN/STOP key
Drive/stop is operated when panel operation is
selected.
G
Power supply switch ON/OFF of main power supply of controller
H
Speed adjusting knob
Setting of the value of output voltage
I
JOG display lamp
It lights when JOG can drive.
J
Vib. A display lamp
It lights when constant amplitude function is
ON
LIMIT display lamp
It lights when reaching to limit of correction.
Caution
Only when 2 or 3 (both are on the operation
panel) is selected by the function J02, the
RUN/STOP key can be used.
MIN
MAX
JAPAN
AC200-230V 50/60Hz 12A
V.F. CONTROLLER
RUN
Vib.A
LIMIT
RoHS
G
E
H
B
C
D
A
K
J
F
I