H group (Related to data setting)
Display Name
Content
H00
Input logic of IN1
Initial value: 0
(Refer to P.45 for display of input
state of IN1)
Signal logic of sensor input 1(IN1) is reversed. Time until actual operation changes
depending on setting times of ON delay timer 1and the OFF delay timer 1.
0: When the terminal IN1 is connected to 0V (Low level), the OFF delay timer 1
works to stop the driving. The ON delay timer 1 works at the High level to start
the driving.
1: When the terminal IN1 is connected to 0V, the ON delay timer 1 works to start
the driving. The OFF delay timer 1 works at the High level to stop the driving.
H01
ON delay timer 1
Initial value: 0.0 (second)
Set range:
0.0~60.0seconds
The time between when sensor 1 (IN1) stops to confirm the work and when parts
feeder starts driving is set.
Note) It is effective only when the data selection (J02) of the driving method is 0, 1
or 3 (the use of the overflow detection sensor is selected).
H02
OFF delay timer 1
Initial value: 0.0 (second)
Set range:
0.0~30.0seconds
The time between when sensor 1 (IN1) starts to confirm the work and when parts
feeder stops driving is set.
Note) It is effective only when the data selection (J02) of the driving method is 0, 1
or 3 (the use of the overflow detection sensor is selected).
H03
Impossible of choice
This function cannot be used.
H04
Impossible of choice
This function cannot be used.
H05
Impossible of choice
This function cannot be used.
H06
Soft start time
Initial value: 0.5 (second)
Set range:
0.0~5.0 seconds
Set the soft start time. The output voltage is gradually raised from 0V until it
reaches the set value. The time of the raising is set. The minimum set time is 0.0
second, but actually it is about 50msec.
H07
Soft stop time
Initial value: 0.3 (second)
Set range:
0.0~5.0seconds
Set the soft stop time. The output voltage is gradually lowered from the set value
until it reaches 0V. The time of the lowering is set. The minimum set time is 0.0
second, but actually it is about 50msec.
H08
Use of work shortage timer
Initial value: 0
It selects as whether work shortage timer is used at IN1.
0: Does not use
1: Uses the signal IN1
(Work shortage is detected with overflow sensor.)
In case it is set 1, IN1 signal is sent to work shortage timer (H09) and work
shortage reset timer (H10).