2 Technical Data
PCS-9785 Satellite-Synchronized Clock
2-1
Date: 2019-07-05
2.1 Electrical Specification
2.1.1 Power Supply
Standard
IEC 60255-26:2013
Rated voltage
110Vdc/125Vdc, 220Vdc/250Vdc
110Vac/220Vac
Operating range
88~300Vdc
88~264Vac
Permissible AC ripple voltage Max. 15% of the nominal auxiliary voltage
Burden
Quiescent condition
Operating condition
28W
30W
2.1.2 Binary Output for Block/Alarm
Output mode
Potential free contact
Maximal system voltage
380Vac, 250Vdc
Voltage withstand
1000V RMS in 1min
Continuous carry
8A
Short duration current
12A@3s, 15A@1s, [email protected], [email protected]
Breaking capacity (L/R=40ms)
0.70A@48Vdc
0.40A@110Vdc
0.30A@125Vdc
0.20A@220Vdc
0.15A@250Vdc
Pickup time
10ms
Drop off time
6ms
Durability
Min.10,000 operations
2.2 Mechanical Specification
Mounting Way
Flush mounted
Chassis color
Silver grey
Weight per device
Approx. 8kg
Chassis material
Aluminum alloy
Location of terminal
Rear panel of the device
Device structure
Plug-in modular type @ rear side, integrated front plate
Protection class
Standard
IEC 60255-1:2009
HMI side
IP51
Terminal side
IP30
Other sides
IP50
2.3 Ambient Temperature and Humidity Range
Standard
IEC 60255-1:2009