- 27 -
INSTALLATION INSTRUCTIONS
G015
For NPK 2000 ft. lb. class hammers
(with top brackets that include joint fittings).
5.1.
For units with SAE style joint fittings.
a. Disconnect the hammer hoses (m5 and m6) from the top bracket joint
fittings (m18a, m18b). Remove the existing adapter fittings (m16) and
discard.
b. Install the special adapter tee fittings (a62) into the top bracket joint fittings
(m18a, m18b). Reconnect the hammer hoses (m5 and m6).
c. Install straight fitting (g19) into the special adapter fitting. Use the port that
closely faces the center of the top bracket, which will allow for the best hose
routing. Install #6 SAE plug (AS) in the opposite port.
d. Install hose line (a64). Route hose from return side joint fitting (m18b),
through top bracket burnout, to port labeled “R
OIL
” on the grease pump (FZ).