Manual, F/T Sensor, Axia80
Document #9620-05-B-Axia80-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
B-29
7.
Specifications
Some requirements and specifications for the Axia80 sensor are covered in the following sections. For more
information, refer to the customer drawing.
7.1 Environmental Conditions
Table 6.1—Environmental Conditions
Parameter
Value
Storage Temperature, °C
-20 to +85
Operating Temperature, °C
0 to +65
Relative Humidity
<95%, non-condensing
7.2
Electrical Specifications
Table 6.2—Power Supply
1
Power Source
Voltage
Power Consumption
Minimum
Nominal
Maximum
Maximum
DC Power
12 V
24 V
30 V
1.5 W
Notes:
1.
The power supply input is reverse polarity protected. If the power and ground to the power supply
inputs are plugged in reverse, then the reverse polarity protection stops the incorrectly wired supply
input from damaging or powering on the sensor.
7.3 Calibration Ranges
Table 6.3
—Calibration Range 0 and Calibration Range 1
Model
Axia80-M8
Parameter
Fxy
Fz
Txyz
Calibration Range 0 (SI-150-8)
150 N
470 N
8 Nm
Calibration Range 1 (SI-75-4)
75 N
235 N
4 Nm
Notes:
1.
Each sensor is calibrated with both of these calibration ranges.
Table 6.4
—Calibration Range 0 and Calibration Range 1
Model
Axia80-M20
Parameter
Fxy
Fz
Txyz
Calibration Range 0 (SI-500-20)
500 N
900 N
20 Nm
Calibration Range 1 (SI-200-8)
200 N
360 N
8 Nm
Notes:
1.
Each sensor is calibrated with both of these calibration ranges.
Table 6.5
—Calibration Range 0 and Calibration Range 1
Model
Axia80-M50
Parameter
Fxy
Fz
Txyz
Calibration Range 0 (SI-1500-50)
1200 N
2000 N
50 Nm
Calibration Range 1 (SI-480-20)
480 N
800 N
20 Nm
Notes:
1.
Each sensor is calibrated with both of these calibration ranges.