Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
C-79
Table 11.2—XML Elements in netftapi2.xml
XML Element
Data Type
Description
Reference
setmce
USINT
Threshold processing status
moncon
mce
USINT[16]
Threshold statements’ individual enabling
mcx
USINT[16]
Threshold statements’ selected axes
mcc
USINT[16]
Threshold statements’ comparisons
mcv
DINT[16]
Threshold statements’ counts values for comparison
mco
HEX8[16]
Threshold statements’ output codes
cfgcalsel
USINT
Calibration used by active configuration
config
cfgcalsn
STRING8
Serial number of active configuration’s calibration
cfgfu
USINT
Force units used by active configuration
scfgfu
STRING8
Name of force units used by active configuration
cfgtu
USINT
Torque units used by active configuration
scfgtu
STRING8
Name of torque units used by active configuration
cfgtdu
USINT
Tool transformation distance units that are used by an
active configuration.
scfgtdu
STRING16
Name of tool transformation distance units that are
used by an active configuration.
cfgtau
USINT
Tool transformation rotation units that are used by an
active configuration.
scfgtau
STRING8
Name of tool tranformation rotation units that are
used by an active configuration.
cfgtfx
REAL[6]
Tool transformation distances and rotations that are
applied by active configuration.
comnetdhcp
ENABL
DHCP behavior setting
comm
comnetip
STRING15 Static IP address
comnetmsk
STRING15 Static IP subnet mask
comnetgw
STRING15 Static IP gateway
nethwaddr
STRING17 Ethernet MAC address
commrdtrate
UDINT
RDT output rate
comrdtbsiz
USINT
RDT Buffer Mode buffer size
mfgdighwa
STRING17 Ethernet MAC Address
manuf
mfgdigsn
STRING8
Digital board serial number
mfgdigver
STRING8
Digital board firmware revision
mfgdigrev
STRING8
Digital board hardware revision
mfgtxdmdl
STRING16 Analog board location
manuf
netip
STRING15 IP address in use
runrate
UDINT
Internal sample rate for strain gage collection
–