448
Remote Gateway 9150 Installation and Administration Guide
Display log definitions
Standard 4.0
Statistic
Definition
LOG NUMBER
39
DESCRIPTION
This log indicates that there an attempt was made to get an
additional trunk on the PSTN.
This message has a corresponding message with same number on
the Remote Gateway 9150 unit board. This can cause a voice call
to fail, depending on the media allowed to communicate with that
remote device and the priority of the call.
However, check for the presence of log number 55 on the RLC to
see if a voice call did not succeed. Look for the presence of log
number 37 on the RLC. It indicates that an attempt was made to
connect the voice call on that medium, but that the medium was not
reachable.
SEVERITY
MINOR
TASK
Network Manager
PRODUCT
RLC, 9150
CANCELLATION
None
ACTION TO BE TAKEN
1) Ensure the PSTN numbers shown in Trunk Configuration are
correct on both the RLC and Remote Gateway 9150 unit.
2) Ensure the trunk route to that Remote Gateway 9100 Series unit
is not busy.
PARAMETERS
1) Remote Gateway 9100 Series unit ID
2) PSTN number attempted
3) A flag to indicate whether attempt is made by remote board or
local board.
a) indicates attempt made by local board
b) indicates attempt made by remote board
DISPLAYED TEXT
Attempt to bring-up additional trunk failed. Remote P1, PSTN
number P2, flag P3
PRODUCES HOST PBX
ALARM AND ALERT
Yes
Summary of Contents for Remote Office 9150
Page 2: ......
Page 4: ......
Page 6: ...iv Remote Gateway 9150 Installation and Administration Guide Publication history Standard 4 0 ...
Page 18: ...xvi Remote Gateway 9150 Installation and Administration Guide Contents Standard 4 0 ...
Page 398: ...370 Remote Gateway 9150 Installation and Administration Guide Troubleshooting Standard 4 0 ...
Page 544: ...516 Remote Gateway 9150 Installation and Administration Guide Glossary Standard 4 0 ...
Page 552: ...524 Remote Gateway 9150 Installation and Administration Guide Fields Index Standard 4 0 ...
Page 569: ......