Appendix A — 2Mb PRI implementation
Page 459 of 492
Option 11C
ISDN BRI Administration and Maintenance
8
Use Overlay 73 to change trunk pad category values
Prompt
Response
Description
REQ
CHG
TYPE
PRI2
2 Mb PRI
FEAT
PADS
PDCA
#
PAD table-0 is default and is hard coded
The following prompts define the pad levels.
The receiving pad code is
r and the transmission pad code is t. These
entries have the range 0-15. The pad values (in decibels) relating to these
codes are shown after this table.
ONP
r t
On-premises extension
DSET
r t
Meridian Digital set
(prompted only if the 2 Mb Gateway feature is
equipped)
Author’s Note—p7/dave/gateway
OPX
r t
Off-premises extension
DTT
r t
Digital TIE trunks
SDTT
r t
digital Satellite TIE trunks
NTC
r t
Nontransmission compensated
TRC
r t
Transmission compensated
DCO
r t
digital COT, FEX, WAT, and DID trunks
VNL
r t
VIA NET LOSS
DTO
r t
2 Mb PRI2 digital TOLL office trunks
ACO
r t
Analog CO or WATS trunks
AFX
r t
Analog FEX trunks
ADD
r t
Analog DID trunks
SATT
r t
analog satellite TIE trunks
ATO
r t
analog TOLL office trunks
PRI2
r t
2 Mb 2 Mb PRI trunk
(prompted only if the 1.5/2 Mb Gateway
feature is equipped and TYPE=2 Mb PRI)
Author’s Note—p7/dave/gateway
Summary of Contents for Meridian 1 Option 11C
Page 2: ......
Page 4: ...553 3011 311 Standard 7 0 May 1999...
Page 12: ...viii Contents 553 3011 311 Standard 7 0 May 1999...
Page 14: ...Page x About this guide 553 3011 311 Standard 7 0 May 1999...
Page 166: ...Page 152 of 492 Chapter 4 Network clocking 553 3011 311 Standard 7 0 May 1999...
Page 318: ...Page 304 of 492 Chapter 6 ISDN BRI trunk implementation 553 3011 311 Standard 7 0 May 1999...
Page 434: ...Page 420 of 492 Chapter 8 Service changes and maintenance 553 3011 311 Standard 7 0 May 1999...
Page 446: ...Page 432 of 492 Chapter 9 ISDN BRI traffic reports 553 3011 311 Standard 7 0 May 1999...
Page 492: ...Page 478 of 492 Appendix A 2Mb PRI implementation 553 3011 311 Standard 7 0 May 1999...